Surgical Table Monitoring

ForeSite™ OR is a continuous monitoring system for clinicians to improve safety of patient positioning in the operating room — and reduce the risk of pressure related surgical complications.

Prevention of Hospital-Acquired Pressure Injuries (HAPIs) remains a crucial clinical challenge especially for those patients undergoing surgery. Pressure injury development in the operating room accounts for up to 45% of all HAPIs.

Download Brochure

Overview

SMART OR SURFACE

ForeSite OR

ForeSite OR’s integrated sensing layer over proprietary multi-layer construction redistributes peak pressures that can cause tissue damage and provides support where pressures build up.

01

Software

Track body surface pressures real time in the operating room.

ForeSite OR’s sensors generate and record real-time images of the body surface pressures that surgical staff can use as part of their preoperative positioning, during, and post-operative plans to reduce the risk of pressure ulcers.

02

Specifications & Performance

The ForeSite OR pressure measuring system is fully enclosed within the OR cushion cover for simple cleaning and sterilization.

The easy-to-use application provides high-resolution, real-time pressure images and pressure measurements. The system runs on a touchscreen and connects via wireless Bluetooth® to the ForeSite pressure sensors. Surface pressure data for surgical procedures can be saved to provide a record for continued patient care or future reference.

Data can then be collected to evaluate the effectiveness of procedures or to support clinical research. OR pad usage is tracked to provide for the management of replacement cycles.

Integrated reliable pressure sensors measure with ±5% accuracy and do not need to be recalibrated

Pressure sensors provide superior image quality with 0.5” sensing points (torso size sensor)

ForeSite OR software’s high-resolution images clearly show the elevated pressures

Touchscreen display, pre-installed software and wireless sensor are hassle-free

Easy-to-use software makes it quick to configure for multiple cushions

Specifications
SURGICAL TABLE CUSHION
SENSEL SIZE (mm)
SENSING AREA (cm x cm)
CALIBRATION RANGE (mmHg)

LX100.17.31.02 (HEAD)

1588

25.7 x 49.2

5-200

LX100.29.31.02 (TORSO)

1588

46 x 49.2

5-200

LX100.31.61.02 (LEGS)

1588

96.8 x 49.2

5-200

Ebook

Ultimate Guide To Pressure Injury Prevention in Hospitals

With tens of thousands of hospital-acquired pressure injuries developing every year in American hospitals, it’s important to implement prevention strategies that work—for your patients, and your staff.

Download Ebook

Need more information?
Let's talk.

We’d love to hear how we can match you with a solution that meets your needs.

Book a Demo